Web of Science: 14 cites, Scopus: 14 cites, Google Scholar: cites,
Ultraviolet (UV-C) inactivation of Enterococcus faecium, Salmonella choleraesuis and Salmonella typhimurium in porcine plasma
Blázquez Salvador, Elena (Institut de Recerca i Tecnologia Agroalimentàries. Centre de Recerca en Sanitat Animal)
Rodríguez, Carmen (APC EUROPE)
Ródenas, Jesús (APC EUROPE)
Pérez de Rozas, Ana (Institut de Recerca i Tecnologia Agroalimentàries. Centre de Recerca en Sanitat Animal)
Segalés Coma, Joaquim (Institut de Recerca i Tecnologia Agroalimentàries. Centre de Recerca en Sanitat Animal)
Polo, Javier (APC EUROPE)

Data: 2017
Resum: The objective of this study was to assess the effectiveness of an ultraviolet (UV-C, 254 nm) irradiation system on reducing the load of Salmonella typhimurium (S. typhimurium), Salmonella choleraesuis (S. choleraesuis) resistant to streptomycin and Enterococcus faecium (E. faecium) inoculated in sterile porcine plasma and then subjected to different UV-C irradiation doses (750, 1500, 3000, 6000 and 9000 J/L) using a pilot plant UV-C device working under turbulent flow. Results indicated that UV-C treatment induced a viability reduction of 0. 38, 1. 18, 3. 59, 4. 72 and 5. 06 log10 S. typhimurium when irradiated at 750, 1500, 3000, 6000 and 9000 J/L, respectively. The observed log10 reduction of S. choleraesuis was 1. 44, 2. 68, 5. 55, 7. 07 and 7. 97 at 750, 1500, 3000, 6000 and 9000 J/L, respectively. The best-fit inactivation for S. choleraesuis was the Weibull distribution curve, while the best-fit curve for S. typhimurium was the Weibull plus tail model, indicating that around 10 2 cfu/mL resistant S. typhimurium was detected when the liquid plasma was UV-C irradiated at doses up to 9000 J/L. Viability reduction for E. faecium was 0. 44, 1. 01, 3. 70, 5. 61 and 6. 22 log10 when irradiated at 750, 1500, 3000, 6000 and 9000 J/L, respectively, with no bacterial resistance observed with UV-C doses of 6000 J/L or higher. The biphasic model was the best fit model for the inactivation curve for E. faecium. For the three microorganisms tested, about a 4 log-unit reduction was achieved when the liquid plasma was irradiated at 3000J/L. Overall results demonstrate the usefulness of the UV-C system to inactivate bacteria in liquid plasma before spray-drying. We conclude that the UV-C system can provide an additional biosafety feature that can be incorporated into the manufacturing process for spray-dried animal plasma.
Nota: Altres ajuts: Secretaria de Universitats i Recerca del Departament d'Economia i Coneixement de la Generalitat de Catalunya 2014DI066
Drets: Aquest document està subjecte a una llicència d'ús Creative Commons. Es permet la reproducció total o parcial, la distribució, la comunicació pública de l'obra i la creació d'obres derivades, fins i tot amb finalitats comercials, sempre i quan es reconegui l'autoria de l'obra original. Creative Commons
Llengua: Anglès
Document: Article ; recerca ; Versió publicada
Publicat a: PloS one, Vol. 12 (april 2017) , ISSN 1932-6203

DOI: 10.1371/journal.pone.0175289
PMID: 28399166


11 p, 1.5 MB

El registre apareix a les col·leccions:
Documents de recerca > Documents dels grups de recerca de la UAB > Centres i grups de recerca (producció científica) > Ciències de la salut i biociències > Centre de Recerca en Sanitat Animal (CReSA-IRTA)
Articles > Articles de recerca
Articles > Articles publicats

 Registre creat el 2022-02-07, darrera modificació el 2023-12-12



   Favorit i Compartir