Web of Science: 0 cites, Scopus: 1 cites, Google Scholar: cites
Novel autocalibration strategy for disposable potentiometric test strips
Calvo-Lopez, Antonio (Universitat Autònoma de Barcelona. Departament de Química)
Garrido-Carretero, Laia (Universitat Autònoma de Barcelona. Departament de Química)
Alonso Chamarro, Julián (Universitat Autònoma de Barcelona. Departament de Química)
Puyol Bosch, M. del Mar (Universitat Autònoma de Barcelona. Departament de Química)

Data: 2025
Resum: Potentiometry, particularly involving ion-selective electrodes (ISEs), is widely employed in laboratories due to its selectivity and compatibility with portable instruments. However, ISEs face a drawback -instability over time, requiring frequent calibration for precise and reliable results. This manual calibration process contradicts the user-friendly concept and inhibits the development of single-use quantitative devices for untrained personnel. To solve this limitation, a novel potentiometric autocalibration procedure, which is automated, is presented, and successfully tested for the first time with versatile potentiometric disposable test strips to perform the determination of chloride ion in sweat as a demonstrator. The test strips are based on a cyclic olefin copolymer platform, where two identical Ag/AgCl chloride ISEs are integrated, one acting as indicator and the other as reference electrode. Comparison of chloride results in real sweat samples between those obtained with the proposed test strips performing the novel autocalibration procedure and using ion chromatography reveals that the automated procedure effectively allows quantitative chloride ion analysis with good analytical features: linear range from 10 to 150 mM (covering the pathological range), average inter-method error of 7 % and average RSD between test strips of 4 %. By carefully selecting the initial solution composition in direct contact with each electrode, the autocalibration ensures that potentiometric test strips can be calibrated just before its use without requiring conscious user involvement. This breakthrough not only streamlines the process but also opens the possibility for the development of cheap disposable potentiometric test strips, accessible to non-experts operators, to quantitatively determine selected analytes in different fields.
Ajuts: Agencia Estatal de Investigación PID2020-117216RB-I00
Agència de Gestió d'Ajuts Universitaris i de Recerca 2021/SGR-00124
Nota: Altres ajuts: acords transformatius de la UAB
Drets: Aquest document està subjecte a una llicència d'ús Creative Commons. Es permet la reproducció total o parcial, la distribució, la comunicació pública de l'obra i la creació d'obres derivades, sempre que no sigui amb finalitats comercials, i sempre que es reconegui l'autoria de l'obra original. Creative Commons
Llengua: Anglès
Document: Article ; recerca ; Versió publicada
Matèria: Autocalibration ; Chloride ion ; Cystic fibrosis ; Disposable test strips ; Ion selective electrodes ; Potentiometry ; Sweat
Publicat a: Journal of Electroanalytical Chemistry, Vol. 977 (January 2025) , art. 118829, ISSN 1572-6657

DOI: 10.1016/j.jelechem.2024.118829


8 p, 783.7 KB

El registre apareix a les col·leccions:
Articles > Articles de recerca
Articles > Articles publicats

 Registre creat el 2025-01-24, darrera modificació el 2025-03-04



   Favorit i Compartir