Reference Ranges of 2-Dimensional Placental Biometry and 3-Dimensional Placental Volume between 11 and 14 Weeks of Gestation
Trilla, Cristina (Institut de Recerca Sant Pau)
Parra Roca, Juan (Institut de Recerca Sant Pau)
Llurba, E. (Institut de Recerca Sant Pau)
Universitat Autònoma de Barcelona

Data: 2024
Resum: The purpose of this study was to provide gestational age (GA) specific reference ranges for 2-dimensional (2D) placental biometry and 3-dimensional (3D) placental volume between 11 and 14 weeks of gestation. Placental biometry including 2D and 3D variables was calculated in 1142 first-trimester singleton pregnancies with non-complicated outcome between September 2016 and February 2020. Ultrasound datasets were obtained at the time of the first-trimester ultrasound, and 2D basal plate (BP), chorionic plate (CP), placental thickness (PT), and 3D placental volume (PV) were measured following a standardized methodology. Reference ranges for each variable were calculated according to GA and crown-rump-length (CRL). A total of 1142 uncomplicated pregnancies were considered for analysis. All placental measurements increased significantly between 11 and 14 weeks, especially for PT (39. 64%) and PV (64. 4%). Reference ranges were constructed for each 2D and 3D first-trimester placental variable using the best-fit regression model for the predicted mean and SD as a function of GA and CRL. Reference ranges of 2D placental biometry and 3D placental volume between 11 and 14 weeks of gestation were constructed, generating reference values. Placental biometry showed a progressive increase during the first trimester. This highlights the importance of using reference range charts according to GA.
Drets: Aquest document està subjecte a una llicència d'ús Creative Commons. Es permet la reproducció total o parcial, la distribució, la comunicació pública de l'obra i la creació d'obres derivades, fins i tot amb finalitats comercials, sempre i quan es reconegui l'autoria de l'obra original. Creative Commons
Llengua: Anglès
Document: Article ; recerca ; Versió publicada
Matèria: 2-dimensional ultrasound ; 3-dimensional ultrasound ; First trimester ; Placental biometry ; Placental insufficiency ; Placental volume ; Preeclampsia
Publicat a: Diagnostics, Vol. 14 Núm. 14 (july 2024) , p. 1556, ISSN 2075-4418

DOI: 10.3390/diagnostics14141556
PMID: 39061694


10 p, 2.7 MB