Articles

Articles 56 registres trobats  inicianterior16 - 25següentfinal  anar al registre: La cerca s'ha fet en 0.00 segons. 
16.
25 p, 6.3 MB Optimal Control Strategy of a Sewer Network / Vasiliev, Iulian (Dunarea de Jos University of Galati) ; Luca, Laurentiu (Dunarea de Jos University of Galati) ; Barbu, Marian (Dunarea de Jos University of Galati) ; Vilanova i Arbós, Ramon (Universitat Autònoma de Barcelona. Departament de Telecomunicació i Enginyeria de Sistemes) ; Caraman, Sergiu (Dunarea de Jos University of Galati)
This paper proposes a series of methods to increase the efficiency of the operating of a sewer network that serves a medium-sized city with a population of 250,000 inhabitants. The sewer network serves five areas of the city and consists of seven tanks that communicate with one another and with the treatment plant through pipes. [...]
2022 - 10.3390/w14071062
Water, Vol. 14 Núm. 7 (March 2022) , art. 1062  
17.
18 p, 2.0 MB Tannery Wastewater Recalcitrant Compounds Foster the Selection of Fungi in Non-Sterile Conditions : A Pilot Scale Long-Term Test / Spennati, Francesco (Consorzio Cuoiodepur) ; La China, Salvatore (University of Modena and Reggio-Emilia. Department of Life Sciences) ; Siracusa, Giovanna (University of Pisa. Department of Biology) ; Di Gregorio, Simona (University of Pisa. Department of Biology) ; Bardi, Alessandra (University of Florence. Department of Civil and Environmental Engineering) ; Tigini, Valeria (University of Turin. Department of Life Sciences and Systems Biology) ; Mori, Gualtiero (Consorzio Cuoiodepur) ; Gabriel, David (Universitat Autònoma de Barcelona. Departament d'Enginyeria Química, Biològica i Ambiental) ; Munz, Giulio (University of Florence. Department of Civil and Environmental Engineering)
This study demonstrated that a microbial community dominated by fungi can be selected and maintained in the long-term under non-sterile conditions, in a pilot-scale packed-bed reactor fed with tannery wastewater. [...]
2021 - 10.3390/ijerph18126348
International journal of environmental research and public health, Vol. 18, Issue 12 (June 2021) , art. 6348  
18.
41 p, 543.0 KB Recovery of polyhydroxyalkanoates (PHAs) from wastewater : a review / Mannina, Giorgio (Università degli Studi di Palermo. Dipartimento di Ingegneria) ; Presti, Dario (Universitat Autònoma de Barcelona. Departament d'Enginyeria Química, Biològica i Ambiental) ; Montiel Jarillo, Gabriela (Universitat Autònoma de Barcelona. Departament d'Enginyeria Química, Biològica i Ambiental) ; Carrera, Julian (Universitat Autònoma de Barcelona. Departament d'Enginyeria Química, Biològica i Ambiental) ; Suárez Ojeda, María Eugenia (Universitat Autònoma de Barcelona. Departament d'Enginyeria Química, Biològica i Ambiental)
Polyhydroxyalkanoates (PHAs) are biopolyesters accumulated as carbon and energy storage materials under unbalanced growth conditions by various microorganisms. They are one of the most promising potential substitutes for conventional non-biodegradable plastics due to their similar physicochemical properties, but most important, its biodegradability. [...]
2020 - 10.1016/j.biortech.2019.122478
Bioresource Technology, Vol. 297 (Feb. 2020), art. 122478  
19.
56 p, 1.9 MB Effective dampening of temperature effects in an anammox reactor treating real mainstream wastewater / Juan Díaz, Xènia (Universitat Autònoma de Barcelona. Departament d'Enginyeria Química, Biològica i Ambiental) ; Pérez Cañestro, Julio (Universitat Autònoma de Barcelona. Departament d'Enginyeria Química, Biològica i Ambiental) ; Carrera, Julian (Universitat Autònoma de Barcelona. Departament d'Enginyeria Química, Biològica i Ambiental)
The aim of the present study was to evaluate the capability of an up-flow anammox sludge bed reactor (13 L) of dampening a 10 ◦C temperature drop at mainstream conditions while operating at constant nitrogen loading rates (0. [...]
2021 - 10.1016/j.jwpe.2020.101853
Journal of Water Process Engineering, Vol. 40 (April 2021) , art. 101853  
20.
12 p, 2.6 MB Prospects on coupling UV/H2O2 with activated sludge or a fungal treatment for the removal of pharmaceutically active compounds in real hospital wastewater / Mir Tutusaus, Josep Anton (Universitat Autònoma de Barcelona. Departament d'Enginyeria Química, Biològica i Ambiental) ; Jaén-Gil, Adrián (Universitat de Girona) ; Barceló, Damià (Universitat de Girona) ; Buttiglieri, Gianluigi (Universitat de Girona) ; Gonzalez-Olmos, Rafael (Universitat Ramon Llull. Institut Químic de Sarrià-IQS) ; Rodriguez-Mozaz, Sara (Universitat de Girona) ; Caminal i Saperas, Glòria (Institut de Química Avançada de Catalunya) ; Sarrà i Adroguer, Montserrat (Universitat Autònoma de Barcelona. Departament d'Enginyeria Química, Biològica i Ambiental)
Conventional active sludge (AS) process at municipal centralized wastewater treatment facilities may exhibit little pharmaceuticals (PhACs) removal efficiencies when treating hospital wastewater (HWW). [...]
2021 - 10.1016/j.scitotenv.2021.145374
Science of the total environment, Vol. 773 (June 2021) , art. 145374  
21.
23 p, 2.7 MB New approach for regulation of the internal recirculation flow rate by fuzzy logic in biological wastewater treatments / Santín López, Ignacio (Universitat Autònoma de Barcelona. Departament de Telecomunicació i Enginyeria de Sistemes) ; Vilanova i Arbós, Ramon (Universitat Autònoma de Barcelona. Departament de Telecomunicació i Enginyeria de Sistemes) ; Pedret Ferré, Carles (Universitat Autònoma de Barcelona. Departament de Telecomunicació i Enginyeria de Sistemes) ; Barbu, Marian (Universitat Autònoma de Barcelona. Departament de Telecomunicació i Enginyeria de Sistemes)
The internal recirculation plays an important role on the different biological processes of wastewater treatment plants because it has a great influence on the concentration of pollutants, especially nutrients. [...]
2021 - 10.1016/j.isatra.2021.03.028
ISA Transactions, (March 2021)  
22.
33 p, 4.4 MB Quantifying the benefit of a dynamic performance assessment of WWTP / Revollar, Silvana. (Universidad de Salamanca. Departamento de Informática y Automática) ; Meneses Benítez, Montserrat (Universitat Autònoma de Barcelona. Departament de Telecomunicació i Enginyeria de Sistemes) ; Vilanova i Arbós, Ramon (Universitat Autònoma de Barcelona. Departament de Telecomunicació i Enginyeria de Sistemes) ; Vega, Pastora (Universidad de Salamanca. Departamento de Informática y Automática) ; Francisco, Mario (Universidad de Salamanca. Departamento de Informática y Automática)
In this work a comprehensive analysis of the environmental impact of the operation of a wastewater treatment plant (WWTP) using different control strategies is carried out considering the dynamic evolution of some environmental indicators and average operation costs. [...]
2020 - 10.3390/pr8020206
Processes, Vol. 8, Issue 2 (February 2020) , art. 206  
23.
28 p, 2.9 MB Wastewater treatment plant operation : Simple control schemes with a holistic perspective / Revollar, Silvana (Universidad de Salamanca. Departamento de Informática y Automática) ; Vilanova i Arbós, Ramon (Universitat Autònoma de Barcelona. Departament de Telecomunicació i Enginyeria de Sistemes) ; Vega, Pastora (Universidad de Salamanca. Departamento de Informática y Automática) ; Francisco, Mario (Universidad de Salamanca. Departamento de Informática y Automática) ; Meneses Benítez, Montserrat (Universitat Autònoma de Barcelona. Departament de Telecomunicació i Enginyeria de Sistemes)
In this paper, a control approach for improving the overall efficiency of a wastewater treatment plant (WWTP) is presented. It consists of a cascaded control system that uses a global performance indicator as the controlled variable to drive the plant to operating conditions that satisfies trade-offs involved in the WWTP operation, improving the global performance of the plant. [...]
2020 - 10.3390/su12030768
Sustainability, Vol. 12, Issue 3 (February 2020) , art. 768  
24.
24 p, 866.4 KB Eco-Efficiency Assessment of Control Actions in Wastewater Treatment Plants / Revollar, Silvana. (Universidad de Salamanca) ; Meneses Benítez, Montserrat (Universitat Autònoma de Barcelona. Departament de Telecomunicació i Enginyeria de Sistemes) ; Vilanova i Arbós, Ramon (Universitat Autònoma de Barcelona. Departament de Telecomunicació i Enginyeria de Sistemes) ; Vega, Pastora (Universidad de Salamanca) ; Francisco, Mario (Universidad de Salamanca)
This work explores the possibilities of improving the eco-efficiency of Wastewater Treatment Plants (WWTPs) introducing a plant-wide perspective in the formulation of the control strategy. Eco-efficiency goals are contemplated in the analysis of the appropriateness of control actions, considering the seasonal effects of temperature into the decision-making process. [...]
2021 - 10.3390/w13050612
Water, Vol. 13, Núm. 5 (February 2021) , art. 612  
25.
31 p, 2.2 MB Industrial Control under Non-Ideal Measurements : Data-Based Signal Processing as an Alternative to Controller Retuning / Pisa, Ivan (Universitat Autònoma de Barcelona. Departament de Telecomunicació i Enginyeria de Sistemes) ; Morell Pérez, Antoni (Universitat Autònoma de Barcelona. Departament de Telecomunicació i Enginyeria de Sistemes) ; Vilanova i Arbós, Ramon (Universitat Autònoma de Barcelona. Departament de Telecomunicació i Enginyeria de Sistemes) ; López Vicario, José (Universitat Autònoma de Barcelona. Departament de Telecomunicació i Enginyeria de Sistemes)
Industrial environments are characterised by the non-lineal and highly complex processes they perform. Different control strategies are considered to assure that these processes are correctly performed. [...]
2021 - 10.3390/s21041237
Sensors (Basel, Switzerland), Vol. 21, Núm. 4 (February, 2021) , art. 1237  

Articles : 56 registres trobats   inicianterior16 - 25següentfinal  anar al registre:
Us interessa rebre alertes sobre nous resultats d'aquesta cerca?
Definiu una alerta personal via correu electrònic o subscribiu-vos al canal RSS.