Dipòsit Digital de Documents de la UAB 14 registres trobats  1 - 10següent  anar al registre: La cerca s'ha fet en 0.01 segons. 
1.
Development of molecular lateral flow biosensors for non-covered medical needs / Rubio Monterde, Ana ; Quesada Gonzalez, Daniel, dir. ; Merkoçi, Arben, dir.
La pandèmia actual de SARS-CoV-2 ha ressaltat la importància de poder desenvolupar, produir i desplegar ràpidament proves de diagnòstic per a malalties infeccioses emergents, ja que el SARS-CoV-2 no serà l'última amenaça. [...]
La actual pandemia de SARS-CoV-2 ha resaltado la importancia de poder desarrollar, producir y desplegar rápidamente pruebas de diagnóstico para enfermedades infecciosas emergentes, ya que el SARS-CoV-2 no será la última amenaza. [...]
The ongoing SARS-CoV-2 pandemic has highlighted the importance of being able to develop, produce and deploy rapidly diagnostic tests for emerging infectious diseases, as SARS-CoV-2 will not be the last threat. [...]

2023  
2.
27 p, 1.3 MB Toward integrated molecular lateral flow diagnostic tests using advanced micro- and Nnanotechnology / Rubio-Monterde, Ana (Institut Català de Nanociència i Nanotecnologia) ; Quesada-González, Daniel (Paperdrop Diagnostics) ; Merkoçi, Arben (Institut Català de Nanociència i Nanotecnologia)
Introduction: Since the COVID-19 pandemic, some of the routine methods for clinical diagnosis of infectious diseases have become closer to the general population and terms like "PCR" (polymerase chain reaction) and "antigen rapid diagnostic test" (RDT) are not restricted only to the scientific community but now also commonly appear in everyday language. [...]
2023 - 10.1021/acs.analchem.2c04529
Analytical chemistry, Vol. 95, issue 1 (Jan. 2023) , p. 468-489  
3.
12 p, 3.4 MB Integrating gold nanoclusters, folic acid and reduced graphene oxide for nanosensing of glutathione based on "turn-off" fluorescence / Wong, Xin Yi (University of Nottingham Malaysia. Department of Chemical and Environmental Engineering) ; Quesada-González, Daniel (Paperdrop Diagnostics) ; Manickam, Sivakumar (Universiti Teknologi Brunei. Petroleum and Chemical Engineering) ; New, Siu Yee (University of Nottingham Malaysia. School of Pharmacy) ; Muthoosamy, Kasturi (University of Nottingham Malaysia. Centre of Nanotechnology and Advanced Materials) ; Merkoçi, Arben (Institut Català de Nanociència i Nanotecnologia)
Glutathione (GSH) is a useful biomarker in the development, diagnosis and treatment of cancer. However, most of the reported GSH biosensors are expensive, time-consuming and often require complex sample treatment, which limit its biological applications. [...]
2021 - 10.1038/s41598-021-81677-8
Scientific reports, Vol. 11 (January 2021) , art. 2375  
4.
59 p, 2.6 MB Tutorial : design and fabrication of nanoparticle-based lateral-flow immunoassays / Parolo, Claudio (Institut Català de Nanociència i Nanotecnologia) ; Sena Torralba, Amadeo (Institut Català de Nanociència i Nanotecnologia) ; Bergua Canudo, José Francisco (Institut Català de Nanociència i Nanotecnologia) ; Calucho, Enric (Institut Català de Nanociència i Nanotecnologia) ; Fuentes-Chust, Celia (Institut Català de Nanociència i Nanotecnologia) ; Hu, Liming (Institut Català de Nanociència i Nanotecnologia) ; Rivas, Lourdes (Institut Català de Nanociència i Nanotecnologia) ; Álvarez Diduk, Ruslan (Institut Català de Nanociència i Nanotecnologia) ; Nguyen, Emily P. (Institut Català de Nanociència i Nanotecnologia) ; Cinti, Stefano (Università degli Studi di Napoli Federico II) ; Quesada-González, Daniel (Paperdrop Diagnostics) ; Merkoçi, Arben (Institut Català de Nanociència i Nanotecnologia)
Lateral-flow assays (LFAs) are quick, simple and cheap assays to analyze various samples at the point of care or in the field, making them one of the most widespread biosensors currently available. They have been successfully employed for the detection of a myriad of different targets (ranging from atoms up to whole cells) in all type of samples (including water, blood, foodstuff and environmental samples). [...]
2020 - 10.1038/s41596-020-0357-x
Nature Protocols, Vol. 15, issue 12 (Dec. 2020) , p. 3788-3816  
5.
8 p, 1.1 MB Uranium (VI) detection in groundwater using a gold nanoparticle/paper-based lateral flow device / Quesada-González, Daniel (Institut Català de Nanociència i Nanotecnologia) ; Jairo, Grace A. (Tulane University School of Medicine. Department of Biochemistry and Molecular Biology) ; Blake, Robert C. (Xavier University of Louisiana) ; Blake, Diane A. (Tulane University School of Medicine. Department of Biochemistry and Molecular Biology) ; Merkoçi, Arben (Institut Català de Nanociència i Nanotecnologia)
The contamination in groundwater due to the presence of uranium is nowadays a subject of concern due to the severe health problems associated with renal failure, genotoxicity and cancer. The standard methods to detect uranium require time-consuming processes and expensive non-portable equipment, so these measurements are rarely performed in-field, which increases the time until water samples are analysed. [...]
2018 - 10.1038/s41598-018-34610-5
Scientific reports, Vol. 8 (November 2018) , art. 16157  
6.
22 p, 1.5 MB Nanomaterial-based devices for point-of-care diagnostic applications / Quesada-González, Daniel (Institut Català de Nanociència i Nanotecnologia) ; Merkoçi, Arben (Institut Català de Nanociència i Nanotecnologia)
In this review, we have discussed the capabilities of nanomaterials for point-of-care (PoC) diagnostics and explained how these materials can help to strengthen, miniaturize and improve the quality of diagnostic devices. [...]
2018 - 10.1039/c7cs00837f
Chemical Society Reviews, Vol. 47, Issue 13 (July 2018) , p. 4697-4709  
7.
7 p, 700.4 KB Iridium oxide (IV) nanoparticle-based lateral flow immunoassay / Quesada-González, Daniel (Institut Català de Nanociència i Nanotecnologia) ; Sena Torralba, Amadeo (Institut Català de Nanociència i Nanotecnologia) ; Wicaksono, Wiyogo Prio (University of Indonesia. Department of Chemistry) ; De La Escosura-Muñiz, Alfredo (Institut Català de Nanociència i Nanotecnologia) ; Ivandini, Tribidasari A. (University of Indonesia. Department of Chemistry) ; Merkoçi, Arben (Institut Català de Nanociència i Nanotecnologia)
Lateral flow biosensors are paper-based devices that allow the detection of different types of analytes with quickness, robustness and selectivity, without leaving behind paper sensors benefits as low-cost, recyclability and sustainability. [...]
2019 - 10.1016/j.bios.2019.02.049
Biosensors & bioelectronics, Vol. 132 (May 2019) , p. 132-135  
8.
9 p, 524.5 KB Signal enhancement on gold nanoparticle-based lateral flow tests using cellulose nanofibers / Quesada-González, Daniel (Institut Català de Nanociència i Nanotecnologia) ; Stefani, Christina (Institut Català de Nanociència i Nanotecnologia) ; González Tovar, Israel (Universitat de Girona) ; De La Escosura-Muñiz, Alfredo (Institut Català de Nanociència i Nanotecnologia) ; Domingo Marimon, Neus (Institut Català de Nanociència i Nanotecnologia) ; Mutjé, Pere (Universitat de Girona) ; Merkoçi, Arben (Institut Català de Nanociència i Nanotecnologia)
Lateral flow paper-based biosensors merge as powerful tools in point-of-care diagnostics since they are cheap, portable, robust, selective, fast and easy to use. However, the sensitivity of this type of biosensors is not always as high as required, often not permitting a clear quantification. [...]
2019 - 10.1016/j.bios.2019.111407
Biosensors & bioelectronics, Vol. 141 (September 2019) , art. 111407  
9.
8 p, 589.1 KB Iridium oxide (IV) nanoparticle-based electrocatalytic detection of PBDE / Quesada-González, Daniel (Institut Català de Nanociència i Nanotecnologia) ; Baiocco, Alessandra (Università di Roma) ; Martos, Andrea A. (Institut Català de Nanociència i Nanotecnologia) ; De La Escosura-Muñiz, Alfredo (Institut Català de Nanociència i Nanotecnologia) ; Palleschi, Giuseppe (Università di Roma) ; Merkoçi, Arben (Institut Català de Nanociència i Nanotecnologia)
Polybrominated diphenyl ethers (PBDEs) are a type of flame retardants which are currently banned in EU and USA due their hazardousness for humans and mammals. However, these compounds were highly used during more than 30 years and still persist in the environment since they are resistant to degradation. [...]
2019 - 10.1016/j.bios.2018.11.050
Biosensors & bioelectronics, Vol. 127 (February 2019) , p. 150-154  
10.
227 p, 11.8 MB Design and application of nanomaterial-based lateral flow devices / Quesada-González, Daniel ; Merkoçi, Arben, dir. ; Universitat Autònoma de Barcelona. Departament de Química
Els biosensors de fluxe lateral són dispositius basats en paper d'alta rellevància en diagnòstics "point-of-care" i monitoratge ambiental. Aquests dispositius són de baix cost, ràpids, robustos i simples de fer servir. [...]
Lateral flow biosensors are paper-based devices of high relevance in point-of-care diagnostics and environmental monitoring. These devices are low-cost, fast, robust and simple to use. In this research, lateral flow biosensors are applied for the detection of uranium ions in drinking water with high selectivity and low assay time. [...]

[Barcelona] : Universitat Autònoma de Barcelona, 2019.  

Dipòsit Digital de Documents de la UAB : 14 registres trobats   1 - 10següent  anar al registre:
Us interessa rebre alertes sobre nous resultats d'aquesta cerca?
Definiu una alerta personal via correu electrònic o subscribiu-vos al canal RSS.