Sample stability and heparin interference in ionized calcium and ionized magnesium measurements in horses using the Stat Profile Prime Plus co-oximetry electrolyte analyzer
Sanmartí, Julia (Universitat Autònoma de Barcelona. Departament de Medicina i Cirurgia Animals)
Robles-Guirado, José-Ángel (Universitat Autònoma de Barcelona. Departament de Bioquímica i de Biologia Molecular)
José Cunilleras, Eduard (Universitat Autònoma de Barcelona. Departament de Medicina i Cirurgia Animals)
Bassols Teixidó, Anna Maria (Universitat Autònoma de Barcelona. Departament de Bioquímica i de Biologia Molecular)

Fecha: 2023
Resumen: Background: The determination of iCa and iMg is important in veterinary medicine, but their immediate determination in whole blood is not always possible. Their stability in other sample types and the existence of interferences must be evaluated before its use. Objectives: We aimed to analyze the effects of storage time on the stability of iCa, iMg, and other analytes in whole blood, plasma, and serum samples in horses and assess the interference of heparin in these measurements. Methods: Whole blood, heparin-plasma, and serum samples from 10 horses were stored at 4°C and analyzed 1, 2, 3, 4, 5, 6, 7, 8, 24, 48, and 168 hours after sample collection using the Stat Profile Prime Plus Vet equipment (Nova Biomedical, Waltham, MA, USA). Results were analyzed by ANOVA or mixed-effect models. Results: The concentration of iCa, iMg, total calcium (tCa), total magnesium (tMg), and the ratios iCa/tCa and iMg/tMg did not differ up to 168 hours when compared to the initial time. Total Ca, iMg, and tMg were not significantly different among sample types, but iCa concentrations were slightly but significantly lower in plasma. Freezing at −20°C did not affect iCa, iMg, tCa, and tMg. The pH increased in serum and plasma after 8 hours, and a mild negative correlation existed between plasma iCa concentration and pH. A negative correlation was observed also between the ratios iCa/tCa or iMg/tMg and pH in plasma and serum. A significant decrease in iCa and iMg was detected when comparing homemade syringes at high heparin concentration (~200-300 U heparin/mL) and commercial lithium-heparin tubes (20-30 U/mL). Conclusions: Samples stored at 4°C can be used to determine iCa and iMg concentrations up to 7 days after collection. Other metabolites are stable for up to 8 hours; heparin interference should be taken into account if using homemade heparin syringes.
Nota: Altres ajuts: acords transformatius de la UAB
Derechos: Aquest document està subjecte a una llicència d'ús Creative Commons. Es permet la reproducció total o parcial, la distribució, i la comunicació pública de l'obra, sempre que no sigui amb finalitats comercials, i sempre que es reconegui l'autoria de l'obra original. No es permet la creació d'obres derivades. Creative Commons
Lengua: Anglès
Documento: Article ; recerca ; Versió publicada
Materia: Equine ; Ionized calcium ; Ionized magnesium ; Point-of-care ; Sample stability ; Total calcium ; Total magnesium
Publicado en: Veterinary clinical pathology, 2023 , ISSN 1939-165X

DOI: 10.1111/vcp.13200
PMID: 36746672


9 p, 3.8 MB