Modelling the cooling of concrete by piped water
Myers, T. G.
Fowkes, N. D.
Ballim, Y.
Centre de Recerca Matemàtica

Publicación: Centre de Recerca Matemàtica 2010
Descripción: 22 p.
Resumen: Piped water is used to remove hydration heat from concrete blocks during construction. In this paper we develop an approximate model for this process. The problem reduces to solving a one-dimensional heat equation in the concrete, coupled with a first order differential equation for the water temperature. Numerical results are presented and the effect of varying model parameters shown. An analytical solution is also provided for a steady-state constant heat generationmodel. This helps highlight the dependence on certain parameters and can therefore provide an aid in the design of cooling systems.
Derechos: Aquest document està subjecte a una llicència d'ús de Creative Commons, amb la qual es permet copiar, distribuir i comunicar públicament l'obra sempre que se'n citin l'autor original, la universitat i el centre i no se'n faci cap ús comercial ni obra derivada, tal com queda estipulat en la llicència d'ús Creative Commons
Lengua: Anglès
Colección: Centre de Recerca Matemàtica. Prepublicacions
Colección: Prepublicacions del Centre de Recerca Matemàtica ; 921
Documento: Article ; Prepublicació ; Versió de l'autor
Materia: Temperatura ; Models matemàtics ; Anàlisi tèrmica



22 p, 207.0 KB

El registro aparece en las colecciones:
Documentos de investigación > Prepublicacions

 Registro creado el 2010-09-07, última modificación el 2023-02-11



   Favorit i Compartir