Web of Science: 17 citations, Scopus: 19 citations, Google Scholar: citations
Cava wine authentication employing a voltammetric electronic tongue
Cetó Alsedà, Xavier (Universitat Autònoma de Barcelona. Grup de Sensors i Biosensors)
Puig Pujol, Anna (Institut Català de la Vinya i el Vi)
Capdevila Mestres, Josefa (Institut Català de la Vinya i el Vi)
Valle Zafra, Manuel del (Universitat Autònoma de Barcelona. Grup de Sensors i Biosensors)

Date: 2014
Abstract: The application of an Electronic Tongue for the classification of cava samples based on their different ageing times is reported. As such, voltammetric responses were obtained from an array of six bulk-modified graphite-epoxy electrodes, which exhibited marked mix-responses towards the different samples. Obtained responses were then preprocessed employing FFT and the resulting coefficients were input to a LDA model which allowed the classification of the samples according to its vintage time. Besides, a quantitative model employing ANNs was built for the prediction of the total amount of sugar present in the samples, a parameter also used to classify cava samples.
Note: Número d'acord de subvenció MCINN/CTQ2010-17099
Rights: Tots els drets reservats.
Language: Anglès.
Document: article ; recerca ; acceptedVersion
Subject: Electronic tongue ; Linear discriminant analysis ; Artificial neural network ; Cava wine ; Ageing
Published in: Electroanalysis, Vol. 26 Issue 7 (July 2014) , p. 1504-1512, ISSN 1040-0397

DOI: 10.1002/elan.201400057


Post-print
8 p, 1.2 MB

The record appears in these collections:
Articles > Research articles
Articles > Published articles

 Record created 2015-12-15, last modified 2019-02-03



   Favorit i Compartir