Google Scholar: citas
Control of Electron-transfer in Immunonanosensors by Using Polyclonal and Monoclonal Antibodies
Mars, Abdelmoneim (Institut Català de Nanociència i Nanotecnologia)
Parolo, Claudio (Institut Català de Nanociència i Nanotecnologia)
De La Escosura-Muñiz, Alfredo (Institut Català de Nanociència i Nanotecnologia)
Raouafi, Noureddine (Université de Tunis El-Manar)
Merkoçi, Arben (Institut Català de Nanociència i Nanotecnologia)

Fecha: 2016
Resumen: The design and operation of biosensors is not trivial. For instance, variation in the output signal during monitoring of analytes can not usually be controlled. Hence, if such control were possible, and could be triggered on demand, it would greatly facilitate system design and operation. Herein, we report the design of two types of voltamperometric immunosensors, in which the magnitude of the current output signal (differential pulse voltammetry [DPV]) can be increased or decreased as needed. The designed systems use monoclonal and polyclonal anti-human IgG antibodies, conjugated to monopodal ferrocene-modified gold nanoparticles that are casted onto screen-printed carbon electrodes (Ab/mFcL/AuNPs/SPCEs). Upon addition of human IgG as antigen, the systems exhibit opposite responses according to the Ab: the current decreases when monoclonal Ab is used, whereas it increases when polyclonal Ab is used. We attributed the former response to inhibition of electron-transfer (due to the formation of a protein layer), and the latter response, to a global increase in electron transfer (induced by the aggregation of gold nanoparticles). These effects were confirmed by studying a custom-made lipoic acid-based bipodal ligand, which confirmed that the increase in current is effectively induced by the aggregation of the modified nanoparticles (pAb/mFcL/AuNPs). Both sensors have large dynamic ranges, although the pAb-based one was found to be 3. 3-times more sensitive. Tests of selectivity and specificity for ovalbumin, α-lactalbumin and serum bovine albumin showed that the immunosensors are highly selective and specific, even in the presence of up to 1000-fold levels of potentially competitive proteins. The limit of detection for human IgG using the pAb/mFcL/AuNP bioconjugate was estimated to be 0. 85 ng/mL. The pAb/mFcL/AuNPs-based biosensor has used to determine amounts of human IgG in real sample.
Ayudas: Ministerio de Economía y Competitividad SEV-2013-0295
Agència de Gestió d'Ajuts Universitaris i de Recerca 2014/SGR-260
Ministerio de Educación y Ciencia MAT2011-25870
Derechos: Aquest material està protegit per drets d'autor i/o drets afins. Podeu utilitzar aquest material en funció del que permet la legislació de drets d'autor i drets afins d'aplicació al vostre cas. Per a d'altres usos heu d'obtenir permís del(s) titular(s) de drets.
Lengua: Anglès
Documento: Article ; recerca ; Versió acceptada per publicar
Materia: Ferrocene ; Gold Nanoparticles ; Immunonanosensor ; Signal Control ; Voltamperometric Biosensing
Publicado en: Electroanalysis, Vol. 28, Núm. 8 (August 2016) , p. 1795-1802, ISSN 1521-4109

DOI: 10.1002/elan.201500646


Post-print
8 p, 1.6 MB

El registro aparece en las colecciones:
Documentos de investigación > Documentos de los grupos de investigación de la UAB > Centros y grupos de investigación (producción científica) > Ciencias > Institut Català de Nanociència i Nanotecnologia (ICN2)
Artículos > Artículos de investigación
Artículos > Artículos publicados

 Registro creado el 2018-09-18, última modificación el 2024-11-23