Google Scholar: citas
Time course study of long-term biocompatibility and foreign body reaction to intraneural polyimide-based implants
de la Oliva, Natalia (Universitat Autònoma de Barcelona. Institut de Neurociències)
Navarro, X. (Xavier) (Xavier) (Universitat Autònoma de Barcelona. Institut de Neurociències)
Del Valle, Jaume (Institut Català de Nanociència i Nanotecnologia)

Fecha: 2018
Resumen: The foreign body reaction (FBR) against an implanted device is characterized by the formation of a fibrotic tissue around the implant. In the case of interfaces for peripheral nerves, used to stimulate specific group of axons and to record different nerve signals, the FBR induces a matrix deposition around the implant creating a physical separation between nerve fibers and the interface that may reduce its functionality over time. In order to understand how the FBR to intraneural interfaces evolves, polyimide non-functional devices were implanted in rat peripheral nerve. Functional tests (electrophysiological, pain and locomotion) and histological evaluation demonstrated that implanted devices did not cause any alteration in nerve function, in myelinated axons or in nerve architecture. The inflammatory response due to the surgical implantation decreased after 2 weeks. In contrast, inflammation was higher and more prolonged in the device implanted nerves with a peak after 2 weeks. With regard to tissue deposition, a tissue capsule appeared soon around the devices, acquiring maximal thickness at 2 weeks and being remodeled subsequently. Immunohistochemical analysis revealed two different cell types implicated in the FBR in the nerve: macrophages as the first cells in contact with the interface and fibroblasts that appear later at the edge of the capsule. Our results describe how the FBR against a polyimide implant in the peripheral nerve occurs and which are the main cellular players. Increasing knowledge of these responses will help to improve strategies to decrease the FBR against intraneural implants and to extend their usability.
Ayudas: European Commission 611687
Instituto de Salud Carlos III CB06-05-1105
Instituto de Salud Carlos III RD12-0019-0011
Ministerio de Economía y Competitividad SEV-2013-0295
Derechos: Tots els drets reservats.
Lengua: Anglès
Documento: Article ; recerca ; Versió sotmesa a revisió
Materia: Foreign body reaction ; Peripheral nerve interface ; Biocompatibility ; Polyimide ; Nerve electrode
Publicado en: Journal of biomedical materials research : Part A, Vol. 106, Issue 3 (March 2018) , p. 746-757, ISSN 1552-4965

DOI: 10.1002/jbm.a.36274


Preprint
36 p, 1.9 MB

El registro aparece en las colecciones:
Documentos de investigación > Documentos de los grupos de investigación de la UAB > Centros y grupos de investigación (producción científica) > Ciencias de la salud y biociencias > Institut de Neurociències (INc)
Documentos de investigación > Documentos de los grupos de investigación de la UAB > Centros y grupos de investigación (producción científica) > Ciencias > Institut Català de Nanociència i Nanotecnologia (ICN2)
Artículos > Artículos de investigación
Artículos > Artículos publicados

 Registro creado el 2019-10-21, última modificación el 2023-01-26



   Favorit i Compartir