Web of Science: 42 citas, Scopus: 45 citas, Google Scholar: citas,
Effect of inspiratory synchronization during pressure-controlled ventilation on lung distension and inspiratory effort
Rittayamai, Nuttapol (Faculty of Medicine Siriraj Hospital)
Beloncle, François (University of Angers)
Goligher, Ewan C. (University Health Network and Mount Sinai Hospital)
Chen, Lu (Keenan Research Centre and Li Ka Shing Knowledge Institute)
Mancebo, Jordi (Institut d'Investigació Biomèdica Sant Pau)
Richard, Jean-Christophe M. (INSERM UMR 955 eq 13)
Brochard, Laurent (Keenan Research Centre and Li Ka Shing Knowledge Institute)
Universitat Autònoma de Barcelona

Fecha: 2017
Resumen: In pressure-controlled (PC) ventilation, tidal volume (V) and transpulmonary pressure (P) result from the addition of ventilator pressure and the patient's inspiratory effort. PC modes can be classified into fully, partially, and non-synchronized modes, and the degree of synchronization may result in different V and P despite identical ventilator settings. This study assessed the effects of three PC modes on V, P, inspiratory effort (esophageal pressure-time product, PTP), and airway occlusion pressure, P. We also assessed whether P can be used for evaluating patient effort. Prospective, randomized, crossover physiologic study performed in 14 spontaneously breathing mechanically ventilated patients recovering from acute respiratory failure (1 subsequently withdrew). PC modes were fully (PC-CMV), partially (PC-SIMV), and non-synchronized (PC-IMV using airway pressure release ventilation) and were applied randomly; driving pressure, inspiratory time, and set respiratory rate being similar for all modes. Airway, esophageal pressure, P, airflow, gas exchange, and hemodynamics were recorded. V was significantly lower during PC-IMV as compared with PC-SIMV and PC-CMV (387 ± 105 vs 458 ± 134 vs 482 ± 108 mL, respectively; p < 0. 05). Maximal P was also significantly lower (13. 3 ± 4. 9 vs 15. 3 ± 5. 7 vs 15. 5 ± 5. 2 cmHO, respectively; p < 0. 05), but PTP was significantly higher in PC-IMV (215. 6 ± 154. 3 vs 150. 0 ± 102. 4 vs 130. 9 ± 101. 8 cmHO × s × min, respectively; p < 0. 05), with no differences in gas exchange and hemodynamic variables. PTP increased by more than 15% in 10 patients and by more than 50% in 5 patients. An increased P could identify high levels of PTP. Non-synchronized PC mode lowers V and P in comparison with more synchronized modes in spontaneously breathing patients but can increase patient effort and may need specific adjustments. Clinical Trial Registration Clinicaltrial. gov # NCT02071277.
Derechos: Aquest document està subjecte a una llicència d'ús Creative Commons. Es permet la reproducció total o parcial, la distribució, la comunicació pública de l'obra i la creació d'obres derivades, fins i tot amb finalitats comercials, sempre i quan es reconegui l'autoria de l'obra original. Creative Commons
Lengua: Anglès
Documento: Article ; recerca ; Versió publicada
Materia: Airway pressure release ventilation ; Lung-protective ventilation ; Spontaneous ventilation ; Transpulmonary pressure ; Ventilator-induced lung injury
Publicado en: Annals of Intensive Care, Vol. 7 Núm. 1 (january 2017) , p. 100, ISSN 2110-5820

DOI: 10.1186/s13613-017-0324-z
PMID: 28986852


10 p, 1.2 MB

El registro aparece en las colecciones:
Documentos de investigación > Documentos de los grupos de investigación de la UAB > Centros y grupos de investigación (producción científica) > Ciencias de la salud y biociencias > Institut de Recerca Sant Pau
Artículos > Artículos de investigación
Artículos > Artículos publicados

 Registro creado el 2024-02-02, última modificación el 2024-05-04



   Favorit i Compartir