Abstract: Background: the emission of volatile organic compounds (VOC) during the composting process is mainly responsible for the odors generated in these types of waste treatment plants. In this work, VOC emissions from the source-separated organic fraction of municipal solid waste (OFMSW) composting process have been investigated in 50 L pilot reactors operating under different aeration control strategies during the active decomposition stage. - Results: the VOC emissions from traditional aeration control options such as oxygen feedback control or cyclic on-off aeration have been compared with VOC emissions under an oxygen uptake rate (OUR) control strategy. Total VOC emission (mg C m⁻³) and VOC composition (%) have been determined during the first active decomposition stage of composting. Study of VOC composition indicated a high presence of terpenes. Carcinogenic compounds, such as furans, have occasionally been found at very low concentration. Results indicate some differences in VOC composition according to the aeration strategy used. - Conclusions: the evolution of total VOC emissions was relatively similar, being high in the first days of the process. However, the results obtained show some differences in VOC composition depending on the aeration strategy used. The OUR controller provided a more steady emissions profile, which will help the performance of further gas treatment operations, specially biological systems.
Grants: Ministerio de Ciencia e Innovación CTM2012-33663
Ministerio de Ciencia e Innovación BES-2010-038756
Rights: Tots els drets reservats.
Language: Anglès
Document: Article ; recerca ; Versió sotmesa a revisió
Subject: VOC emission ; OFMSW treatment ; Composting ; Process control ; Terpenes ; Oxygen uptake rate
Published in: Journal of chemical technology and biotechnology, Vol. 89, issue 4 (April 2014) , p. 579-586, ISSN 1097-4660

DOI: 10.1002/jctb.4160


Preprint
31 p, 1.1 MB

The record appears in these collections:
Research literature > UAB research groups literature > Research Centres and Groups (research output) > Engineering > Composting Research Group (GICOM)
Articles > Research articles
Articles > Published articles

 Record created 2018-10-02, last modified 2023-10-06



   Favorit i Compartir