Web of Science: 1 citations, Scopus: 1 citations, Google Scholar: citations
Autonomic response to walk tests is useful for assessing outcome measures in people with multiple sclerosis
Kontaxis, Spyridon (Centro de Investigación Biomédica en Red de Bioingeniería, Biomateriales y Nanomedicina)
Laporta, Estela (Centro de Investigación Biomédica en Red de Bioingeniería, Biomateriales y Nanomedicina)
Garcia, Esther (Universitat Autònoma de Barcelona. Departament de Microelectrònica i Sistemes Electrònics)
Guerrero, Ana Isabel (Hospital Universitari Vall d'Hebron)
Zabalza, Ana (Hospital Universitari Vall d'Hebron)
Matteo, Martinis (Vita Salute San Raffaele University)
Lucia, Roselli (Vita Salute San Raffaele University)
Simblett, Sara (King's College London)
Weyer, Janice (RADAR-CNS Patient Advisory Board)
Hotopf, Matthew (King's College London)
Narayan, Vaibhav A. (Research and Development Information Technology)
Rashid, Zulqarnain (King's College London)
Folarin, Amos A. (University College London)
Dobson, Richard J. B. (University College London)
Buron, Mathias Due (Copenhagen University Hospital Rigshospitalet)
Leocani, Letizia (Vita Salute San Raffaele University)
Cummins, Nicholas (King's College London)
Vairavan, Srinivasan (Research and Development Information Technology)
Costa, Gloria Dalla (Vita Salute San Raffaele University)
Magyari, Melinda (Copenhagen University Hospital Rigshospitalet)
Sørensen, Per Soelberg (Copenhagen University Hospital Rigshospitalet)
Nos, Carlos (Hospital Universitari Vall d'Hebron)
Bailón, Raquel (Centro de Investigación Biomédica en Red de Bioingeniería, Biomateriales y Nanomedicina)
Comi, Giancarlo (Casa di Cura del Policlinico (Milà, Itàlia))
the RADAR-CNS Consortium, None (The RADAR-CNS Consortium)

Date: 2023
Abstract: The aim of this study was to evaluate the association between changes in the autonomic control of cardiorespiratory system induced by walk tests and outcome measures in people with Multiple Sclerosis (pwMS). Electrocardiogram (ECG) recordings of 148 people with Relapsing-Remitting MS (RRMS) and 58 with Secondary Progressive MS (SPMS) were acquired using a wearable device before, during, and after walk test performance from a total of 386 periodical clinical visits. A subset of 90 participants repeated a walk test at home. Various MS-related symptoms, including fatigue, disability, and walking capacity were evaluated at each clinical visit, while heart rate variability (HRV) and ECG-derived respiration (EDR) were analyzed to assess autonomic nervous system (ANS) function. Statistical tests were conducted to assess differences in ANS control between pwMS grouped based on the phenotype or the severity of MS-related symptoms. Furthermore, correlation coefficients (r) were calculated to assess the association between the most significant ANS parameters and MS-outcome measures. People with SPMS, compared to RRMS, reached higher mean heart rate (HRM) values during walk test, and larger sympathovagal balance after test performance. Furthermore, pwMS who were able to adjust their HRM and ventilatory values, such as respiratory rate and standard deviation of the ECG-derived respiration, were associated with better clinical outcomes. Correlation analyses showed weak associations between ANS parameters and clinical outcomes when the Multiple Sclerosis phenotype is not taken into account. Blunted autonomic response, in particular HRM reactivity, was related with worse walking capacity, yielding r = 0. 36 r = 0. 29 (RRMS) and r > 0. 5 (SPMS). A positive strong correlation r > 0. 7 r > 0. 65 between cardiorespiratory parameters derived at hospital and at home was also found. Autonomic function, as measured by HRV, differs according to MS phenotype. Autonomic response to walk tests may be useful for assessing clinical outcomes, mainly in the progressive stage of MS. Participants with larger changes in HRM are able to walk longer distance, while reduced ventilatory function during and after walk test performance is associated with higher fatigue and disability severity scores. Monitoring of disorder severity could also be feasible using ECG-derived cardiac and respiratory parameters recorded with a wearable device at home.
Rights: Aquest document està subjecte a una llicència d'ús Creative Commons. Es permet la reproducció total o parcial, la distribució, la comunicació pública de l'obra i la creació d'obres derivades, fins i tot amb finalitats comercials, sempre i quan es reconegui l'autoria de l'obra original. Creative Commons
Language: Anglès
Document: Article ; recerca ; Versió publicada
Subject: Autonomic nervous system ; Disability ; ECG-derived respiration ; Fatigue ; Heart rate variability ; Relapsing-remitting multiple sclerosis ; Secondary progressive multiple sclerosis ; Walking capacity
Published in: Frontiers in physiology, Vol. 14 (april 2023) , ISSN 1664-042X

DOI: 10.3389/fphys.2023.1145818
PMID: 37089424


13 p, 527.1 KB

The record appears in these collections:
Articles > Research articles
Articles > Published articles

 Record created 2023-11-14, last modified 2024-02-05



   Favorit i Compartir