Google Scholar: cites
Application of short-wave pocket-sized near-infrared spectrophotometer to predict milk quality traits
Guerra, Alberto (Università di Padova)
Marchi, Massimo De (Università di Padova)
Niero, Giovanni (Università di Padova)
Chiarin, Elena (Università di Padova)
Manuelian, Carmen L (Universitat Autònoma de Barcelona. Departament de Ciència Animal i dels Aliments)

Publicació: American Dairy Science Association, 2024
Resum: Portable-hand-held devices based on near-infrared (NIR) technology have improved and are gaining popularity, even if their implementation in milk has been barely evaluated. Thus, the aim of the present study was to assess short-wave pocket-sized NIR devices' feasibility to predict milk quality. A total of 331 individual milk samples from different cow breeds and herds were collected in 2 consecutive days for chemical determination and spectral collection by using 2 pocket-sized NIR spectrophotometers working in the range of 740-1070 nm. The reference data was matched with the corresponding spectrum and modified-partial least-squares regression models were developed. A 5-fold cross-validation was applied to evaluate individual devices' performance and an external-validation with 25% of the data set as the validation set was applied for the final models. Results revealed that both devices' absorbance was highly correlated but greater for instrument A than B. Thus, the final models were built by averaging the spectra from both devices for each sample. The fat content prediction model was adequate for quality control with a coefficient of determination (R 2 ExV) and a residual predictive deviation (RPD ExV) in external validation of 0. 93 and 3. 73, respectively. Protein and casein content as well as fat-to-protein ratio prediction models might be used for a rough screening (R 2 ExV > 0. 70; RPD ExV > 1. 73). However, poor prediction models were obtained for all the other traits with an R 2 ExV between 0. 43 (urea) and 0. 03 (somatic cell count), and a RPD ExV between 1. 18 (urea) and 0. 22 (somatic cell count). In conclusion, short-wave portable-hand-held NIR devices accurately predicted milk fat content, and protein, casein, and fat-to-protein ratio might be applied for rough screening. It seems that there is not enough information in this NIR region to develop adequate prediction models for lactose, somatic cell count, urea, and freezing point.
Drets: Aquest document està subjecte a una llicència d'ús Creative Commons. Es permet la reproducció total o parcial, la distribució, la comunicació pública de l'obra i la creació d'obres derivades, fins i tot amb finalitats comercials, sempre i quan es reconegui l'autoria de l'obra original. Creative Commons
Llengua: Anglès
Document: Article ; recerca ; Versió publicada
Matèria: Cow ; Pocket ; Milk composition ; Near-infrared spectroscopy
Publicat a: Journal of dairy science, ISSN 1525-3198

DOI: 10.3168/jds.2023-24302
PMID: 38246541


7 p, 488.8 KB