Web of Science: 1 citas, Scopus: 1 citas, Google Scholar: citas,
Time course of electrical activity of the diaphragm (EAdi) in the peri extubation period and its role as predictor of extubation failure in difficult to wean patients
Parrilla-Gómez, Francisco José (Institut Hospital del Mar d'Investigacions Mèdiques)
Roche-Campo, Ferran (Hospital de Tortosa Verge de la Cinta)
Italiano, Stefano (Hospital Clínic i Provincial de Barcelona)
Parrilla-Gómez, Andrés (Institut Hospital del Mar d'Investigacions Mèdiques)
Morán Chorro, Indalecio (Institut de Recerca Sant Pau)
Mancebo Cortes, Jordi (Institut de Recerca Sant Pau)
Maraffi, Tommaso (Hôpital Intercommunal de Créteil (França))

Fecha: 2024
Resumen: Weaning patients from mechanical ventilation is crucial in the management of acute respiratory failure (ARF). Spontaneous breathing trials (SBT) are used to assess readiness for extubation, but extubation failure remains a challenge. Diaphragmatic function, measured by electrical activity of the diaphragm (EAdi), may provide insights into weaning outcomes. This prospective, observational study included difficult-to-wean patients undergoing invasive mechanical ventilation. EAdi was recorded before, during, and after extubation. Patients were categorized into extubation success and failure groups based on reintubation within 48 h. Statistical analysis assessed EAdi patterns and predictive value. Thirty-one patients were analyzed, with six experiencing extubation failure. Overall, EAdi increased significantly between the phases before the SBT, the SBT and post-extubation period, up to 24 h (p < 0. 001). EAdi values were higher in the extubation failure group during SBT (p = 0. 01). An EAdi.
Derechos: Aquest document està subjecte a una llicència d'ús Creative Commons. Es permet la reproducció total o parcial, la distribució, i la comunicació pública de l'obra, sempre que no sigui amb finalitats comercials, i sempre que es reconegui l'autoria de l'obra original. No es permet la creació d'obres derivades. Creative Commons
Lengua: Anglès
Documento: Article ; recerca ; Versió publicada
Materia: Weaning ; Extubation ; Electrical activity of the diaphragm ; Mechanical ventilation ; Spontaneous breathing trial
Publicado en: Critical care, Vol. 28 (september 2024) , ISSN 1466-609X

DOI: 10.1186/s13054-024-05092-x
PMID: 39289731


10 p, 1.9 MB

El registro aparece en las colecciones:
Documentos de investigación > Documentos de los grupos de investigación de la UAB > Centros y grupos de investigación (producción científica) > Ciencias de la salud y biociencias > Institut de Recerca Sant Pau
Artículos > Artículos de investigación
Artículos > Artículos publicados

 Registro creado el 2025-02-01, última modificación el 2026-05-15



   Favorit i Compartir