TlCl:Be,I : a high sensitivity scintillation and Cherenkov radiator for TOF-PET
Kratochwil, Nicolaus 
(European Organization for Nuclear Research. Department of Experimental Physics Department)
Kaneshige, Nathaniel (Radiation Monitoring Devices Inc.)
Terragni, Giulia 
(European Organization for Nuclear Research. Department of Experimental Physics Department)
Cala, Roberto 
(European Organization for Nuclear Research. Department of Experimental Physics Department)
Schott, Jared (Radiation Monitoring Devices Inc.)
van Loef, Edgar 
(Radiation Monitoring Devices Inc.)
Soundara Pandian, Lakshmi
(Radiation Monitoring Devices Inc.)
Roncali, Emilie
(University of California at Davis. Department of Biomedical Engineering)
Glodo, Jaroslaw
(Radiation Monitoring Devices Inc.)
Auffray, Etiennette
(European Organization for Nuclear Research. Department of Experimental Physics Department)
Ariño-Estrada, Gerard
(Institut de Física d'Altes Energies)
| Fecha: |
2025 |
| Resumen: |
The material requirements for gamma-ray detectors for medical imaging applications are multi-fold and sensitivity is often overlooked. High effective atomic number (Z) Cherenkov radiators have raised the attention in the community due to their potential for harvesting prompt photons. A material with one of the highest Z and thus short gamma-ray attenuation length is thallium chloride (TlCl). By doping TlCl with beryllium (Be) or iodine (I), it becomes a scintillator and therefore produces scintillation photons upon gamma-ray interaction on top of the prompt Cherenkov luminescence. The scintillation response of TlCl:Be,I is investigated in terms of intensity, energy resolution, kinetics, and timing capability with and without energy discrimination. The ratio of prompt to slow scintillation photons is used to derive the intrinsic number of produced Cherenkov photons and compared with analytic calculations avoiding complex Monte-Carlo simulations. The experimentally determined number of Cherenkov photons upon 511 keV gamma excitation of 17. 9 ± 4. 6 photons is in line with our simple calculations yielding 14. 5 photons. We observe three scintillation decay time components with an effective decay time of 60 ns. The scintillation light yield of 0. 9 ph/keV is sufficient to discriminate events with low energy deposition in the crystal which is used to improve the measured coincidence time resolution from 360 ps FWHM without energy selection down to 235 ps after energy discrimination and time walk correction for 2. 8 mm thick TlCl:Be,I crystals, and from 580 ps to 402 ps for 15. 2 mm thick ones. Already with the first generation of doped TlCl encouraging timing capability close to other materials with lower effective atomic number has been achieved. |
| Derechos: |
Aquest document està subjecte a una llicència d'ús Creative Commons. Es permet la reproducció total o parcial, la distribució, i la comunicació pública de l'obra, sempre que no sigui amb finalitats comercials, i sempre que es reconegui l'autoria de l'obra original. No es permet la creació d'obres derivades.  |
| Lengua: |
Anglès |
| Documento: |
Article ; recerca ; Versió publicada |
| Materia: |
TOF-PET ;
TlCl:Be,I ;
Cherenkov emission ;
Coincidence time resolution (CTR) |
| Publicado en: |
IEEE transactions on radiation and plasma medical sciences, Vol. 9, no. 3 (March 2025) , p. 296-303, ISSN 2469-7303 |
DOI: 10.1109/trpms.2024.3487359
PMID: 40045986
El registro aparece en las colecciones:
Documentos de investigación >
Documentos de los grupos de investigación de la UAB >
Centros y grupos de investigación (producción científica) >
Ciencias >
Institut de Física d’Altes Energies (IFAE) Artículos >
Artículos de investigaciónArtículos >
Artículos publicados