Nocturnal Glucose Profile According to Timing of Dinner Rapid Insulin and Basal and Rapid Insulin Type : An Insulclock® Connected Insulin Cap-Based Real-World Study
Gómez-Peralta, Fernando 
(Hospital General de Segovia)
Valledor, X. (Research and Development Unit. Insulcloud S.L.)
Cotovad, L. 
(Hospital Arquitecto Marcide)
Pujante, P. 
(Hospital Universitario Central de Asturias)
Azriel, S. 
(Hospital Universitario Infanta Sofía)
Vallejo, A. (Research and Development Unit. Insulcloud S.L.)
Corcoy i Pla, Rosa
(Institut de Recerca Sant Pau)
Abreu, Cristina (Hospital General de Segovia)
Fernández-Rubio, Elsa (Hospital Universitario Cruces (Baracaldo, Viscaya))
Pérez-González, Jesús (Research and Development Unit. Insulcloud S.L.)
Ruiz-Valdepeñas, Luis (Research and Development Unit. Insulcloud S.L.)
Universitat Autònoma de Barcelona.
Departament de Medicina
| Fecha: |
2024 |
| Resumen: |
Background: A study to assess the glucose levels of people with type 1 diabetes (T1D) overnight, based on the insulin type and timing. Methods: A real-world, retrospective study of T1D, using multiple daily insulin injections. Continuous glucose monitoring and insulin injection data were collected for ten hours after dinner using the Insulclock connected cap. Meal events were identified using the ROC detection methodology. The timing of the rapid insulin, second injections, and the type of insulin analogs used, were evaluated. Results: The nocturnal profiles (n = 775, 49 subjects) were analyzed. A higher glucose AUC of over 180 mg/dL was observed in subjects with delayed injections (number; %; mg/dL × h): -45-15 min (n = 136; 17. 5%, 175. 9 ± 271. 0); -15-0 min (n = 231; 29. 8%, 164. 0 ± 2 37. 1); 0 + 45 min (n = 408; 52. 6%, 203. 6 ± 260. 9), (p = 0. 049). The use of ultrarapid insulin (FiAsp) (URI) vs. rapid insulin (RI) analogs was associated with less hypoglycemia events (7. 1 vs. 13. 6%; p = 0. 005) and TBR70 (1. 7 ± 6. 9 vs. 4. 6 ± 13. 9%; p = 0. 003). Users of glargine U300 vs. degludec had a higher TIR (70. 7 vs. 58. 5%) (adjusted R-squared: 0. 22, p < 0. 001). The use of a correction injection (n = 144, 18. 6%) was associated with a higher number of hypoglycemia events (18. 1 vs. 9. 5%; p = 0. 003), TBR70 (5. 5 ± 14. 2 vs. 3. 0 ± 11. 1%; p = 0. 003), a glucose AUC of over 180 mg/dL (226. 1 ± 257. 8 vs. 178. 0 ± 255. 3 mg/dL × h; p = 0. 001), and a lower TIR (56. 0 ± 27. 4 vs. 62. 7 ± 29. 6 mg/dL × h; p = 0. 004). Conclusion: The dinner rapid insulin timing, insulin type, and the use of correction injections affect the nocturnal glucose profile in T1D. |
| Derechos: |
Aquest document està subjecte a una llicència d'ús Creative Commons. Es permet la reproducció total o parcial, la distribució, la comunicació pública de l'obra i la creació d'obres derivades, fins i tot amb finalitats comercials, sempre i quan es reconegui l'autoria de l'obra original.  |
| Lengua: |
Anglès |
| Documento: |
Article ; recerca ; Versió publicada |
| Materia: |
Connected insulin pen cap ;
Nocturnal hyperglycemia ;
Nocturnal hypoglycemia ;
Second-generation basal insulin ;
Ultrarapid insulin |
| Publicado en: |
Biomedicines, Vol. 12, Num. 7 (July 2024) , art. 1600, ISSN 2227-9059 |
DOI: 10.3390/biomedicines12071600
PMID: 39062173
El registro aparece en las colecciones:
Documentos de investigación >
Documentos de los grupos de investigación de la UAB >
Centros y grupos de investigación (producción científica) >
Ciencias de la salud y biociencias >
Institut de Recerca Sant PauArtículos >
Artículos de investigaciónArtículos >
Artículos publicados
Registro creado el 2026-01-23, última modificación el 2026-01-27