Web of Science: 12 citas, Scopus: 21 citas, Google Scholar: citas,
Intra-Abdominal Pressure as a Marker of Enteral Nutrition Intolerance in Critically Ill Patients. The PIANE Study
Bordeje, Mª Luisa (Institut Germans Trias i Pujol. Hospital Universitari Germans Trias i Pujol)
Montejo, Juan C. (Hospital Universitario 12 de Octubre (Madrid))
Mateu Campos, M. L. (Consorci Hospitalari Provincial de Castelló)
Solera, Manuel (Hospital San Francisco de Borja)
Acosta, José A. (Hospital General Universitario de Alicante (Alacant, País Valencià))
Juan, Mar (Hospital Clínic Universitari (València))
García-Córdoba, Francisco (Hospital Universitario Los Arcos del Mar Menor)
García-Martínez, Miguel A. (Hospital Universitario de Torrevieja)
Gastaldo, Rosa (Hospital de Manacor)
Universitat Autònoma de Barcelona

Fecha: 2019
Resumen: To determine whether elevated intra-abdominal pressure (IAP) is associated with a higher rate of enteral nutrition-related gastrointestinal (GI) complications; to assess the value of IAP as a predictor of enteral nutrition (EN) intolerance. Intensive Care Unit (ICU) patients on mechanical ventilation requiring at least 5 days of EN were recruited for a prospective, observational, non-interventional, multicenter study. EN was performed and GI complications were managed with an established protocol. IAP was determined via a urinary catheter. Patients who developed any GI complications were considered as presenting EN intolerance. Variables related to EN, IAP and GI complications were monitored daily. Statistical analysis compared patients without GI complications (group A) vs. GI complications (group B). 247 patients were recruited from 28 participating ICUs (group A: 119, group B: 128). No differences between groups were recorded. Patients in group B (p < 0. 001) spent more days on EN (8. 1 ± 8. 4 vs. 18. 1 ± 13. 7), on mechanical ventilation (8. 0 ± 7. 7 vs. 19. 3 ± 14. 9) and in the ICU (12. 3 ± 11. 4 vs. 24. 8 ± 17. 5). IAP prior to the GI complication was (14. 3 ± 3. 1 vs. 15. 8 ± 4. 8) (p < 0. 003). The best IAP value identified for EN intolerance was 14 mmHg but it had low sensitivity and specificity. Although a higher IAP was associated with EN intolerance, IAP alone did not emerge as a good predictor of EN intolerance in critically ill patients.
Derechos: Aquest document està subjecte a una llicència d'ús Creative Commons. Es permet la reproducció total o parcial, la distribució, la comunicació pública de l'obra i la creació d'obres derivades, fins i tot amb finalitats comercials, sempre i quan es reconegui l'autoria de l'obra original. Creative Commons
Lengua: Anglès
Documento: Article ; recerca ; Versió publicada
Materia: Gastrointestinal Diseases - etiology ; Critical Illness - therapy ; Pressure
Publicado en: Nutrients, Vol. 11 Núm. 11 (january 2019) , ISSN 2072-6643

DOI: 10.3390/nu11112616
PMID: 31683850