Web of Science: 3 citations, Scopus: 4 citations, Google Scholar: citations,
Optilene, a new non-absorbable monofilament is safe and effective for CABG anastomosis. OPTICABG - A prospective international, multi-centric, cohort study
Ursulescu, Adrian (Robert Bosch Krankenhaus. Department of Cardiac and Vascular Surgery)
Baumann, Petra (Aesculap AG. Medical Scientific Affairs. Am Aesculap Platz)
Tauron Ferrer, Manel (Hospital de la Santa Creu i Sant Pau (Barcelona, Catalunya))
Contino, Monica (Ospedale Luigi Sacco. Department of Cardiac and Vascular Surgery)
Romagnoni, Claudia (Ospedale Luigi Sacco. Department of Cardiac and Vascular Surgery)
Antona, Carlo (Ospedale Luigi Sacco. Department of Cardiac and Vascular Surgery)
Padró Fernández, José María (Institut d'Investigació Biomèdica Sant Pau)

Date: 2018
Abstract: Introduction: Coronary artery bypass grafting (CABG) is performed to improve quality of life and to reduce cardiac-related mortality and morbidity in patients with coronary artery disease (CAD). The aim of the present observational study was to assess the performance of a new suture material (Optilene) for anastomosis construction in CABG surgery using a routine clinical procedure. Performance was assessed using the incidence of major adverse cardiac and cerebrovascular events (MACCE). Methods: The study was designed as an international, multi-centre, prospective cohort study to evaluate the safety and efficacy of a new non-absorbable monofilament for CABG surgery compared to data published in a previous meta-analysis. Optilene suture was used to create the distal and proximal coronary artery anastomoses. The primary endpoint was the cumulative MACCE rate up to discharge. Secondary parameters were intraoperative handling of the suture material and QoL up to 3 months after surgery. Patients were examined 30 days and 3 months postoperatively. Results: In total, 199 patients were enrolled in 3 centres in Europe. The cumulative CABG adverse event rate up to the day of discharge was 3%, in contrast to the 8. 46% given by the data generated by Nalysnyk et al. A t-test showed that our CABG rate was significantly lower. QoL significantly increased from preoperatively until 3 months after surgery. Ease of handling the suture material was rated as very good. Conclusion: Optilene suture material represents a safe and effective alternative to existing sutures used in CABG surgery for anastomosis construction.
Note: Altres ajuts: B.Braun Surgical SA, Barcelona, Spain.
Rights: Aquest document està subjecte a una llicència d'ús Creative Commons. Es permet la reproducció total o parcial, la distribució, i la comunicació pública de l'obra, sempre que no sigui amb finalitats comercials, i sempre que es reconegui l'autoria de l'obra original. No es permet la creació d'obres derivades. Creative Commons
Language: Anglès
Document: Article ; recerca ; Versió publicada
Subject: CABG ; Off-pump ; On-pump ; Anastomosis ; Monofilament suture
Published in: Annals of Medicine and Surgery, Vol. 35 (november 2018) , p. 13-19, ISSN 2049-0801

DOI: 10.1016/j.amsu.2018.09.005
PMID: 30258627


7 p, 367.3 KB