Web of Science: 5 cites, Scopus: 6 cites, Google Scholar: cites,
Exploring Vision-Related Quality of Life : A Qualitative Study Comparing Patients' Experience of Cataract Surgery with a Standard Monofocal IOL and an Enhanced Monofocal IOL
Blancafort Alias, Sergi (Universitat Autònoma de Barcelona. Fundació Salut i Envelliment)
Del Campo Carrasco, Zoraida (Institut d'Investigació Biomèdica Sant Pau)
Salvador-Miras, Ignacio (Institut d'Investigació Biomèdica Sant Pau)
Luna Mariné, Sabina (Institut d'Investigació Biomèdica Sant Pau)
Gómez Prieto, María José (Institut d'Investigació Biomèdica Sant Pau)
Liñán Martín, Francesca (Institut d'Investigació Biomèdica Sant Pau)
Salvà Casanovas, Antoni (Universitat Autònoma de Barcelona. Fundació Salut i Envelliment)

Data: 2022
Resum: To explore quality of life related with intermediate vision of patients before and after cataract surgery, and to make patients' experience available for the design of future scales that assess visual function related with intermediate distance. A qualitative research methodology based on thematic content analysis was used to explore vision-related quality of life based on the experiences of patients with cataract. Patients were recruited at the Service of Ophthalmology of the Hospital de Sant Pau (Barcelona, Spain). Data were collected through nineteen semi-structured interviews conducted with patients diagnosed with cataract and implanted with a standard aspheric monofocal intraocular lens (IOL) (Tecnis ® ZA9003) (n = 6), an enhanced monofocal IOL (Tecnis ® Eyhance ICB000) (n = 6), and patients from the waiting list (n = 7). The data analysis consisted in coding, aggregation, and theme development of the transcribed audios. Patients on waiting lists reported difficulty and insecurity in performing daily and meaningful tasks related to near visual ranges (eg: threading a needle, reading price tags), intermediate (eg: using a computer or dialling numbers on a smartphone), and distant (eg: recognizing faces, walking on uneven surfaces). Patients after surgery with the standard IOL reported improvement in performing activities mainly in the distant visual range, but also the need for a better communication with clinical staff to adjust their own expectations on the results of the surgery. Finally, patients implanted with the enhanced IOL reported satisfaction and improved visual function in performing daily activities, especially those related to the intermediate visual range. Our exploratory study found that patients after cataract surgery with the enhanced IOL reported a better performance in activities that require the intermediate vision. These results will inform the development of scales to assess vision-related quality of life in the intermediate visual range prioritizing outcomes according to patients' daily and meaningful activities.
Drets: Aquest document està subjecte a una llicència d'ús Creative Commons. Es permet la reproducció total o parcial, la distribució, la comunicació pública de l'obra i la creació d'obres derivades, sempre que no sigui amb finalitats comercials, i sempre que es reconegui l'autoria de l'obra original. Creative Commons
Llengua: Anglès
Document: Article ; recerca ; Versió publicada
Matèria: Quality of life ; Cataract ; Qualitative research ; Intraocular lenses
Publicat a: Clinical Ophthalmology (Auckland, N.Z.), Vol. 16 (may 2022) , p. 1641-1652, ISSN 1177-5483

DOI: 10.2147/OPTH.S358386
PMID: 35656389


12 p, 403.2 KB

El registre apareix a les col·leccions:
Documents de recerca > Documents dels grups de recerca de la UAB > Centres i grups de recerca (producció científica) > Ciències de la salut i biociències > Fundació Salut i Envelliment UAB
Documents de recerca > Documents dels grups de recerca de la UAB > Centres i grups de recerca (producció científica) > Ciències de la salut i biociències > Institut de Recerca Sant Pau
Articles > Articles de recerca
Articles > Articles publicats

 Registre creat el 2022-07-23, darrera modificació el 2023-11-29



   Favorit i Compartir