Google Scholar: citas
Extraction of artefactual MRS patterns from a large database using non-negative matrix factorization
Hernández-Villegas, Yanisleydis (Universitat Autònoma de Barcelona. Departament de Bioquímica i de Biologia Molecular)
Ortega-Martorell, Sandra (Liverpool John Moores University)
Arús i Caraltó, Carles (Universitat Autònoma de Barcelona. Institut de Biotecnologia i de Biomedicina "Vicent Villar Palasí")
Vellido, Alfredo (Universitat Politècnica de Catalunya)
Julià Sapé, Ma. Margarita (Universitat Autònoma de Barcelona. Institut de Biotecnologia i de Biomedicina "Vicent Villar Palasí")

Fecha: 2022
Resumen: Despite the success of automated pattern recognition methods in problems of human brain tumor diagnostic classification, limited attention has been paid to the issue of automated data quality assessment in the field of MRS for neuro-oncology. Beyond some early attempts to address this issue, the current standard in practice is MRS quality control through human (expert-based) assessment. One aspect of automatic quality control is the problem of detecting artefacts in MRS data. Artefacts, whose variety has already been reviewed in some detail and some of which may even escape human quality control, have a negative influence in pattern recognition methods attempting to assist tumor characterization. The automatic detection of MRS artefacts should be beneficial for radiology as it guarantees more reliable tumor characterizations, as well as the development of more robust pattern recognition-based tumor classifiers and more trustable MRS data processing and analysis pipelines. Feature extraction methods have previously been used to help distinguishing between good and bad quality spectra to apply subsequent supervised pattern recognition techniques. In this study, we apply feature extraction differently and use a variant of a method for blind source separation, namely Convex Non-Negative Matrix Factorization, to unveil MRS signal sources in a completely unsupervised way. We hypothesize that, while most sources will correspond to the different tumor patterns, some of them will reflect signal artefacts. The experimental work reported in this paper, analyzing a combined short and long echo time 1H-MRS database of more than 2000 spectra acquired at 1. 5T and corresponding to different tumor types and other anomalous masses, provides a first proof of concept that points to the possible validity of this approach.
Ayudas: Ministerio de Economía y Competitividad SAF2014-52332-R
Agència de Gestió d'Ajuts Universitaris i de Recerca 2017/FI_B_00758
Ministerio de Sanidad y Consumo CB06/01/0010
Derechos: Aquest material està protegit per drets d'autor i/o drets afins. Podeu utilitzar aquest material en funció del que permet la legislació de drets d'autor i drets afins d'aplicació al vostre cas. Per a d'altres usos heu d'obtenir permís del(s) titular(s) de drets.
Lengua: Anglès
Documento: Article ; recerca ; Versió sotmesa a revisió
Materia: Acquisition Methods ; Artifacts and corrections ; Methods and Engineering ; MR Spectrosocpy (MRS) and Spectroscopic Imaging (MRSI) Methods ; Post-acquisition Processing
Publicado en: NMR in biomedicine, Vol. 35, Issue 4 (April 2022) , art. e4193, ISSN 1099-1492

DOI: 10.1002/nbm.4193
PMID: 31793715


Preprint
63 p, 5.8 MB

El registro aparece en las colecciones:
Documentos de investigación > Documentos de los grupos de investigación de la UAB > Centros y grupos de investigación (producción científica) > Ciencias de la salud y biociencias > Instituto de Biotecnología y de Biomedicina (IBB)
Artículos > Artículos de investigación
Artículos > Artículos publicados

 Registro creado el 2025-01-29, última modificación el 2025-06-04



   Favorit i Compartir