Google Scholar: cites
Towards a New Standard : Prospective Validation of Ex Vivo Fusion Confocal Microscopy for Intraoperative Margin Assessment in Breast-Conserving Cancer Surgery
Humaran, D. (Universitat Autònoma de Barcelona)
Castillo, A. (Institut Germans Trias i Pujol. Hospital Universitari Germans Trias i Pujol)
Blay, Lidia (Universitat Autònoma de Barcelona. Departament de Cirurgia)
Pascual Miguel, Iciar (Universitat Autònoma de Barcelona. Departament de Cirurgia)
Karol Matute-Molina (Institut Germans Trias i Pujol. Hospital Universitari Germans Trias i Pujol)
Pérez-Anker, Javiera (Hospital Clínic i Provincial de Barcelona)
Puig, Susana (Hospital Clínic i Provincial de Barcelona)
Fernández, Pedro Luis (Institut Germans Trias i Pujol. Hospital Universitari Germans Trias i Pujol)
Julián, Joan F. (Institut Germans Trias i Pujol. Hospital Universitari Germans Trias i Pujol)

Data: 2025
Resum: Background/Objectives: Accurate intraoperative margin assessment is essential for ensuring complete tumour excision in breast-conserving surgery, minimising local recurrence, and avoiding reoperations. Ex vivo fusion confocal microscopy (EVFCM) provides real-time, high-resolution imaging of fresh, unfixed tissues that closely resembles conventional histological imaging. This study aimed to validate the diagnostic performance and clinical feasibility of EVFCM for real-time intraoperative margin assessment during breast cancer surgery. Methods: A prospective observational diagnostic validation study was conducted using 144 breast tissue specimens. The samples were stained with acridine orange and fast green and scanned using a VivaScope 2500M-G4 system. Two breast pathologists independently evaluated the EVFCM images, blinded to the conventional histology results, which served as the reference standard. The diagnostic accuracy, sensitivity, specificity, and interobserver agreement were calculated using Cohen's κ. Results: Interobserver agreement was almost perfect for neoplasia detection (97. 3%, κ = 0. 942) and tumour type classification (93. 8%, κ = 0. 883). The EVFCM achieved 93. 7% sensitivity and specificity, with 94. 0% accuracy for tumour detection (κ = 0. 929, p < 0. 001); 95. 8% accuracy for tumour type classification (κ = 0. 925, p < 0. 001); and 95. 1% accuracy for invasive subtype identification (κ = 0. 907, p < 0. 001). For margin assessment, EVFCM achieved 80% sensitivity, 100% specificity, and 99. 3% accuracy (κ = 0. 857, p < 0. 001), whereas margin distance evaluation (<2 mm vs. ≥2 mm) yielded 75% sensitivity, 100% specificity, and 98. 6% accuracy (κ = 0. 854, p < 0. 001). Conclusions: EVFCM enables rapid, high-resolution imaging of fresh breast tissue, facilitating real-time intraoperative margin evaluation with excellent diagnostic concordance and workflow efficiency. Its integration into surgical practice could reduce re-excisions, enhance oncological safety, and improve patient outcomes in breast-conserving surgeries.
Drets: Aquest document està subjecte a una llicència d'ús Creative Commons. Es permet la reproducció total o parcial, la distribució, la comunicació pública de l'obra i la creació d'obres derivades, fins i tot amb finalitats comercials, sempre i quan es reconegui l'autoria de l'obra original. Creative Commons
Llengua: Anglès
Document: Article ; recerca ; Versió publicada
Matèria: Breast-conserving surgery ; Intraoperative margin assessment ; Ex vivo fusion confocal microscopy ; Digital microscopy ; Breast cancer diagnosis
Publicat a: Cancers, Vol. 17, Num. 23 (November 2025) , art. 3848, ISSN 2072-6694

DOI: 10.3390/cancers17233848


19 p, 3.7 MB

El registre apareix a les col·leccions:
Articles > Articles de recerca
Articles > Articles publicats

 Registre creat el 2025-12-18, darrera modificació el 2025-12-19



   Favorit i Compartir