Operational evaluation of the earlobe arterialized blood collector in critically ill patients
Vaquer, Sergi (Parc Taulí Hospital Universitari. Institut d'Investigació i Innovació Parc Taulí (I3PT))
Masip, Jordi (Parc Taulí Hospital Universitari. Institut d'Investigació i Innovació Parc Taulí (I3PT))
Gili, Gisela (Parc Taulí Hospital Universitari. Institut d'Investigació i Innovació Parc Taulí (I3PT))
Gomà, Gemma (Parc Taulí Hospital Universitari. Institut d'Investigació i Innovació Parc Taulí (I3PT))
Oliva, Joan Carles (Parc Taulí Hospital Universitari. Institut d'Investigació i Innovació Parc Taulí (I3PT))
Frechette, Alexandre (Science, Technology & Engineering, Wyle GmbH, Cologne, Germany)
Evetts, Simon (Science, Technology & Engineering, Wyle GmbH, Cologne, Germany)
Russomano, Thais (King's College London)
Artigas Raventós, Antoni (Parc Taulí Hospital Universitari. Institut d'Investigació i Innovació Parc Taulí (I3PT))
Universitat Autònoma de Barcelona

Data: 2015
Resum: The new Earlobe Arterialized Blood Collector (EABC®) is a minimally invasive prototype system able to perform capillary blood collection from the earlobe (EL) with minimal training and risk. This system could improve medical emergency management in extreme environments. Consequently, a prospective validation study was designed to evaluate operational performance of the EABC® in a cohort of critically ill patients. Arterialized capillary blood was sampled from the EL of 55 invasively ventilated patients using the EABC® following a validated procedure. Operational characteristics such as the number of cuts and cartridges required, sampling failure/success ratio, bleeding complications, storage requirements and other auxiliary aspects were recorded. Result turnaround laboratory times (TAT) were compared with published references. Blood collection was as easily performed on one earlobe as the other. Twenty-six minutes (mean 25. 8; SD = 3. 8) were required to obtain results, 15 min for patient preparation (mean 15. 3; SD = 2. 6) + 11 min for sampling and analysis (mean 11. 4; SD = 2. 1), which is similar to published hospital reference laboratory TAT. The average number of cartridges required was 1. 3 (1-3; mode = 1) with the mean number of cut attempts being 1. 2 (1-4; mode = 1). Problems/difficulties occurred in 59% of cases but were mainly attributed to patient's demographic characteristics, with only 10% attributable to the collector (superficial cut, blood leak, collector misalignment and obstructed vision). Haemostasis was quickly achieved with minimum complications. Storage of the complete sampling kit required a 300 × 300 × 300 mm box. Two 9-V batteries were used during the 2-year study period. The new EABC® system concept is safe, fast and easy to use. Observed problems/difficulties are easily amendable with certain design modifications. Definitive versions of the prototype have the potential for significant benefits for isolated and extreme environments in medicine.
Drets: Aquest document està subjecte a una llicència d'ús Creative Commons. Es permet la reproducció total o parcial, la distribució, la comunicació pública de l'obra i la creació d'obres derivades, fins i tot amb finalitats comercials, sempre i quan es reconegui l'autoria de l'obra original. Creative Commons
Llengua: Anglès
Document: Article ; recerca ; Versió publicada
Matèria: Acute respiratory failure ; Space medicine ; Capillary blood ; Intensive care medicine ; Mechanical ventilation
Publicat a: Extreme Physiology & Medicine, Vol. 4 (april 2015) , ISSN 2046-7648

DOI: 10.1186/s13728-015-0025-x
PMID: 25838884


6 p, 865.4 KB

El registre apareix a les col·leccions:
Documents de recerca > Documents dels grups de recerca de la UAB > Centres i grups de recerca (producció científica) > Ciències de la salut i biociències > Institut d’Investigació i Innovació Parc Taulí (I3PT)
Articles > Articles de recerca
Articles > Articles publicats

 Registre creat el 2018-01-31, darrera modificació el 2024-02-29



   Favorit i Compartir